samples vb.net
Dear dialogic support,,i have buy dialogic card (D/4PCI-U) and i want to build a call center application.did you have a vb.net or c# sample that shows how to connect to the board, and read the numbers...
View ArticleUser-defined events
I am converting a Natural Access application to HMP (which obviously means drastic surgery). One of the issues is that I have a third-party speech recognition application running as a separate process,...
View ArticleLong time to complete fx_stopch after received DIS
Hi,I have setup fax reception on the incoming fax channel for G711. Then, I received RE-INVITE for T38 from remote side. I try to stop the current fax activity but it consumed 5.5 seconds to complete...
View ArticleDialogic card D/600JCT-2E1 compatible with hp server
hello ,I want to know is what the HP ProLiant Gen8 DL380p is compatible with dialogic card D/600JCT-2E1. or a reference in the HP servers that will comptaible with cards dialogic.Best Regards
View ArticleRuntime Error on rvcommon.dll on D/480JCT-2T1 Board
Hi, We have built a IVR system using D/480JCT-2T1 board on Windows server 2008 R2 standard 64-bit machine to host 48 lines. We installed Dialogic (R) System Release 6.0 PCI Redistribute Edition for...
View ArticleConnecting to another SIP Server
Hi.We need a solution to connect an IVR using DNI board into another SIP Server with VoIP technology. Is it possible to connect it using rtp license and IP call control license? Please help me ASAP.Armin
View ArticleDM/IP SIP and NAT Traversal
We have a Global Call app (using a DI/0408-LS-A-R2) that accepts inbound calls from a telco service provider via SIP. Everything works fine when we have our box listen to a public IP. However, we'd...
View ArticleSIP Device names
Apologies if this is a newbie question but:int mode = SR_POLLMODE;if (sr_setparm (SRL_DEVICE, SR_MODEID, &mode) != -1){ // Enable the event handler if (sr_enbhdlr (EV_ANYDEV, EV_ANYEVT,...
View ArticleDialogic D120 causing gateway module to short out
I have a customer using an Avaya PBX (Avaya Communications Manager (CM) 6). They have their analog lines connecting to modules in a gateway. They were initially running one D120 without issue. They...
View ArticleHMP 4.1 Linux Playing Vox File before gc_AnswerCall
Hi,I am trying to set up IVR response on my SIP server before calling gc_AnswerCall. I connected ip devices with voice device and called dx_play and it works if i call gc_AnswerCall function . If i...
View ArticleBest way to find the end of voicemail greeting
Hello,I have tried several settings and will keep trying but thought I would throw this out there. What is the best way to detect the end of a voicemail/answering machine message in order to leave a...
View ArticleStandard Runtime Library on Windows Server 2012 32bit OK ?
We use D120JCTLSEW boards.I need to port from Windows 2008 to Windows 2012 OSOur product runs on 64bit 2008 from app built on 32bit Windows 2003 OS (32bit SRL lib)Can i simply run this on 2012, or...
View ArticleMultiple DNI boards give CT Bus error
Im trying to figure out a problem with server which has multiple DNI boards. The server has 2 DNI1210TEPE2HMP boards and also the correct licensing for it. The problem is when starting the system the...
View Articlesr_WaitThreadDeviceGroup() doesn't retrieve some events on HMP Linux
I have an application that makes use of the "thread device group" functionality in the Standard Runtime Library. After opening my primary board with gc_OpenEx(), I pass the line device id to...
View Articleipm_InitResponseSend raise IPMEV_ERROR
Hi,I used this function to send initResponseboolInitResponseSend (){IPM_INIT_RESPONSE initResp;IPM_NBUP_INIT_RESPONSE nbupResp;// Initialize the main structureINIT_IPM_INIT_RESPONSE...
View ArticleDialogic Diva PRI/E1-30 PCI card not compatible with HP Proliant Gen9 server
The drivers do not work, dialogic tech support have attempted to resolve but could not. They tried latest software release 8.5WIN Update 14A workaround using a generic mircosoft driver worked...
View ArticleSDP on INVITE in 1pcc mode from HMP application
I have an HMP application that runs in 1pcc mode.I am unable to make outbound calls with a single major hosted PBX provider because they always reply "603 Decline".After much debugging at the hosted...
View ArticleHMP with Call Script app (VoiceGuide): "488 hot acceptable here" error for...
Hello,We are using HMP with IVR app called VoiceGuide for our IVR solution.After upgrading the software VoiceGuide, we get "488 not acceptable here" error upon "re-INVITE."The call script used for this...
View ArticleHMP 4.0 BICC how to bridge 2 calls
Hi,My system dial to party A, and party B. After A answer and B answer, I want to bridge call between A and B for conversation between A and B. How can I do?I use BICC with IPM and MMThank you very much
View ArticleDialogic D/82JCT-U card issues
Doubt I am in the right spot, but here goes: I have a Dialogic D/82JCT-U card, which I have put in a machine with the SR6 software. After I do the Autodiscover Device, and the card is seen in the...
View Article